Avalon-firestyles 34 DVL User Manual

Browse online or download User Manual for Kiln Avalon-firestyles 34 DVL. Avalon Firestyles 34 DVL User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
DVL GSR2 NB
Insert
Owner’s Manual
WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
HOT GLASS WILL CAUSE
BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
Tested and Listed by
ANSI Z21.88-2014
CSA 2.33-2014
Direct Vent Fireplace Insert
Masonry or Factory-Built
(Metal) Wood-Burning
Fireplace
Residential or Mobile Home
This appliance may be installed in an aftermarket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com
Copyright 2014, T.I. $10.00 4140813 100-01294
Page view 0
1 2 3 4 5 6 ... 45 46

Summary of Contents

Page 1 - DVL GSR2 NB

DVL GSR2 NB Insert Owner’s Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causin

Page 2 - 2 Introduction

10 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Factory-Built (Metal) Wood-Burning Fireplace Requirements NO

Page 3 - Table of Contents 3

Installation (for qualified installers only) 11 © Travis Industries 4140813 100-01294 Leveling Bolts This heater includes front and rear leveli

Page 4 - 4 Safety Precautions

12 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Clearances Due to the high temperature of the heater, it sho

Page 5 - Safety Precautions 5

Installation (for qualified installers only) 13 © Travis Industries 4140813 100-01294 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARN

Page 6

14 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Vent Requirements Travis Industries manufactures a vent kit

Page 7 - Order of Installation

Installation (for qualified installers only) 15 © Travis Industries 4140813 100-01294 Vent Restrictor WARNING: Restrictor adjustment should onl

Page 8 - Additional Items Required

16 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Vent Location  A vent restrictor is built into the applian

Page 9 - Fireplace Requirements

Installation (for qualified installers only) 17 © Travis Industries 4140813 100-01294 Vent Connector Removal and Installation  The vent connec

Page 10 - Hearth Requirements

18 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Vent Connector Removal and Installation (continued) Vent Co

Page 11 - Electrical Requirements

Installation (for qualified installers only) 19 © Travis Industries 4140813 100-01294 Surround Panel Installation NOTE: The insert may be instal

Page 12 - Clearances

2 Introduction © Travis Industries 4140813 100-01294 Introduction We welcome you as a new owner of a DVL Insert. In purchasing this fireplace inse

Page 13 - Shutoff Valve (secured to

20 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 1-Piece Surround Panel  DVL – 34” by 44” 96100319  DV

Page 14 - Vent Requirements

Installation (for qualified installers only) 21 © Travis Industries 4140813 100-01294 2. Attach the surround panel as shown below.

Page 15 - Vent Installation

22 Finalizing the Installation © Travis Industries 4140813 100-01294 Glass Frame Removal and Installation A barrier designed to reduce the risk of

Page 16 - Vent Configurations

Finalizing the Installation 23 © Travis Industries 4140813 100-01294 Glass Frame Removal and Installation (continued) The glass latch can come lo

Page 17

24 Finalizing the Installation © Travis Industries 4140813 100-01294 Steps for Finalizing the Installation 1. Remove the glass (see page 22). NOTE

Page 18 - Vent Connector Installation

Finalizing the Installation 25 © Travis Industries 4140813 100-01294 5. Install the burner and media (and firebacks if applicable). 6. Replace

Page 19 - Surround Panel Installation

26 Operation © Travis Industries 4140813 100-01294 Before You Begin  Read this entire manual before you use your new heater (especially the sectio

Page 20 - 1-Piece Surround Panel

Operation 27 © Travis Industries 4140813 100-01294 Remote Set-Up Verify the Switch is on “REMOTE” The battery holder has a switch built into it (se

Page 21

28 Operation © Travis Industries 4140813 100-01294 Location of Controls Direct Operation The fireplace may be directly operated from the battery ho

Page 22

Operation 29 © Travis Industries 4140813 100-01294 Starting the Fireplace for the First Time  Burn the heater at a high setting with the blower

Page 23

Table of Contents 3 © Travis Industries 4140813 100-01294 Introduction ... 2Important Informa

Page 24 - AAA Battery

30 Operation © Travis Industries 4140813 100-01294 Remote Operation When the switch on the battery holder is set to “REMOTE” the transmitter operate

Page 25 - Air Shutter Adjustment

Operation 31 © Travis Industries 4140813 100-01294 Manual On-Off / Smart Thermostat / Standard Thermostat Use the thermostat button to cycle throug

Page 26 - 26 Operation

32 Operation © Travis Industries 4140813 100-01294 Mode Controls (Flame, Blower, Light, Comfort Control) Use the mode button to cycle through the fo

Page 27 - Operation 27

Operation 33 © Travis Industries 4140813 100-01294 Mode Controls - continued Accent Light The Accent Light (night light) inside the heater may be

Page 28 - 28 Operation

34 Operation © Travis Industries 4140813 100-01294 Low Battery Indicator Transmitter Batteries The transmitter has a battery-level indicator. When i

Page 29 - Operation 29

Operation 35 © Travis Industries 4140813 100-01294 Child-Proof Feature The child proof feature disables the control buttons, preventing un-wanted u

Page 30 - 30 Operation

36 Maintenance © Travis Industries 4140813 100-01294 DANGER HIGH VOLTAGE: Disconnect power before attempting maintenance or repair. Maintaining Your

Page 31 - Operation 31

Maintenance 37 © Travis Industries 4140813 100-01294 Upper Accent Lights The upper accent light can be accessed by removing the 4 screws with a ¼”

Page 32 - 32 Operation

38 Maintenance © Travis Industries 4140813 100-01294 Yearly Service Procedure  Failure to inspect and maintain the heater may lead to improper com

Page 33 - Operation 33

Maintenance 39 © Travis Industries 4140813 100-01294 Troubleshooting Table Problem: Possible Cause: Don't Call for Service Until You: Main

Page 34

4 Safety Precautions © Travis Industries 4140813 100-01294  Failure to follow all of the requirements may result in property damage, bodily injury

Page 35 - Operation 35

40 Maintenance © Travis Industries 4140813 100-01294 Wiring Diagram Caution: Label all wires prior to disconnection when servicing controls. Wirin

Page 36 - 36 Maintenance

Safety Label 41 © Travis Industries 4140813 100-01294 Safety Label The safety (listing) label is attached to the operating tag (chained to the heat

Page 37 - Maintenance

42 Limited 7 Year Warranty © Travis Industries 4140813 100-01294 Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarr

Page 38 - 38 Maintenance

Optional Equipment (for qualified installers only) 43 © Travis Industries 4140813 100-01294 LP Conversion Instructions The GSR Stepper Motor Kit (

Page 39 - Maintenance 39

44 Optional Equipment (for qualified installers only) © Travis Industries 4140813 100-01294 4 Install the LP (propane) orifices. ORIFICE SIZE

Page 40 - 40 Maintenance

Optional Equipment (for qualified installers only) 45 © Travis Industries 4140813 100-01294 6 Install the LP pilot orifice following the directio

Page 41 - CAUTION:

46 Index © Travis Industries 4140813 100-01294 Accent Light Replacement ... 36 Additional Items Required ...

Page 42 - 42 Limited 7 Year Warranty

Safety Precautions 5 © Travis Industries 4140813 100-01294 Safety Warnings (continued)  Because this heater can be controlled by a thermostat the

Page 43 - LP Conversion Instructions

6 Features and Specifications © Travis Industries 4140813 100-01294 Features - Works During Power Outages (battery backup system) - Blower and Re

Page 44 - Natural Gas LP (Propane)

Installation (for qualified installers only) 7 © Travis Industries 4140813 100-01294 Installation Warnings  Failure to follow all of the requi

Page 45 - LP (Propane) Orifce = .014LP

8 Installation (for qualified installers only) © Travis Industries 4140813 100-01294 Additional Items Required  If using LP (propane) a conver

Page 46 - 46 Index

Installation (for qualified installers only) 9 © Travis Industries 4140813 100-01294 Top Convection Deflector Install the top convection deflect

Comments to this Manuals