864 TRV GS2 (with screen) Installation Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may r
10 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Converting the Fireplace to Top Vent (continued) Remove the 1
Installation (for qualified installers only) 11 Travis Industries 4140611 100-01385 Fireplace Placement Requirements Fireplace must be instal
12 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Televisions Placed Above the Fireplace The following section de
Installation (for qualified installers only) 13 Travis Industries 4140611 100-01385 Using a Buildout Above Fireplace and Television IMPORTANT NO
14 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Using a Buildout Below a Television IMPORTANT NOTE REGARDING TE
Installation (for qualified installers only) 15 Travis Industries 4140611 100-01385 Minimum Framing Dimensions - Rear Vent Configuration Route
16 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Minimum Framing Dimensions - Top Vent Configuration Route th
Installation (for qualified installers only) 17 Travis Industries 4140611 100-01385 Nailing Brackets The fireplace has nailing brackets on both
18 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Corner Installations - Rear Vent Configuration A typical 45° in
Installation (for qualified installers only) 19 Travis Industries 4140611 100-01385 Corner Installations - Top Vent Configuration A typical 45°
2 Introduction © Travis Industries 4140611 100-01385 Overview This manual details the installation requirements for the 864 TRV GS2 fireplace. For
20 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Outdoor Fireplace Installations Travis Industries Inc. gas
Installation (for qualified installers only) 21 Travis Industries 4140611 100-01385 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNIN
22 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Gas Line Location NOTE FOR RIGID PIPE: When using rigid pipe,
Installation (for qualified installers only) 23 Travis Industries 4140611 100-01385 Electrical Connection (required) The electrical line to t
24 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Optional Wall Switch or Thermostat Installation Do not connect
Installation (for qualified installers only) 25 Travis Industries 4140611 100-01385 Vent Requirements The gas appliance and vent system must
26 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Approved Vent Rear vent configurations use 8" (203mm) d
Installation (for qualified installers only) 27 Travis Industries 4140611 100-01385 Approved Vent Configurations Restrictor Position Intake a
28 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Intake Restrictor Adjustment The intake restrictor is located b
Installation (for qualified installers only) 29 Travis Industries 4140611 100-01385 Diffuser Plate Adjustment Certain vent configurations requir
Table of Contents 3 Travis Industries 4140611 100-01385 TableofContentsOverview ...
30 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Rear Vent Configuration with Horizontal Termination (no vertica
Installation (for qualified installers only) 31 Travis Industries 4140611 100-01385 Rear Vent Configuration with Horizontal Termination (with ve
32 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Rear Vent Configuration with Vertical Termination The termin
Installation (for qualified installers only) 33 Travis Industries 4140611 100-01385 Top Vent Configuration with Horizontal Termination The te
34 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Top Vent Configuration with Vertical Termination The termina
Installation (for qualified installers only) 35 Travis Industries 4140611 100-01385 Termination Requirements ! Venting terminals shall not be
36 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Hearth Requirements Do not build a hearth more than 1” (25mm)
Installation (for qualified installers only) 37 Travis Industries 4140611 100-01385 Facing Requirements This appliance is designed to allow f
38 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Facing Overview Upgrade faces are available for this fireplace
Installation (for qualified installers only) 39 Travis Industries 4140611 100-01385 Thin Facing Installation (tile, marble, or other non-combust
4 Safety Precautions Travis Industries 4140611 100-01385 Safety Warnings Failure to follow all of the requirements may result in property damage,
40 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Thin Facing Installation (tile, marble, under 1" (25mm) th
Installation (for qualified installers only) 41 Travis Industries 4140611 100-01385 Thick Facing Installation (stone, brick, or other non-combus
42 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Thick Facing with Fireplace Xtrordinair (FPX) Arched Faces Th
Installation (for qualified installers only) 43 Travis Industries 4140611 100-01385 Thick Facing Installation - Side View DrywallMasonry or oth
44 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Mantel Requirements Combustible Mantels Use the table below
Installation (for qualified installers only) 45 Travis Industries 4140611 100-01385 Installation Example - Build-Out (Dog-House) with Hor. Termi
46 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Installation Example - Build-In with Horizontal Termination
Finalizing the Installation (for qualified installers only) 47 Travis Industries 4140611 100-01385 Steps for Finalizing the Installation 1. Rem
48 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 9. Check the air shutter following the directio
Finalizing the Installation (for qualified installers only) 49 Travis Industries 4140611 100-01385 Barrier Removal A barrier designed to reduc
Safety Precautions 5 Travis Industries 4140611 100-01385 Safety Warnings (continued) Because this heater can be controlled by a thermostat the
50 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 Glass Frame Removal and Installation Warning: T
Finalizing the Installation (for qualified installers only) 51 Travis Industries 4140611 100-01385 Glass Frame Removal and Installation (continu
52 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 Log Set Installation Log Set Overview When insta
Finalizing the Installation (for qualified installers only) 53 Travis Industries 4140611 100-01385 Back Log The back log has two pockets that in
54 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 Front Left Log The front left log has a channel
Finalizing the Installation (for qualified installers only) 55 Travis Industries 4140611 100-01385 Center Twig The center twig is shown below.
56 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 Left Twig The left twig has a hole on the bottom
Finalizing the Installation (for qualified installers only) 57 Travis Industries 4140611 100-01385 Center Log The center log has a hole on the b
58 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 Ember Installation A bag of embers is provided t
Finalizing the Installation (for qualified installers only) 59 Travis Industries 4140611 100-01385 LP Conversion Instructions Install the conver
6 Features and Specifications Travis Industries 4140611 100-01385 Installation Options Residential or Mobile Home Straight or Corner Placemen
60 Finalizing the Installation (for qualified installers only) Travis Industries 4140611 100-01385 3 Follow the directions below to replace the or
Finalizing the Installation (for qualified installers only) 61 Travis Industries 4140611 100-01385 4 Install the LP pilot orifice following the
62 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 Fireback Installation WARNING: Turn off gas to the appl
Optional Equipment (for qualified installers only) 63 Travis Industries 4140611 100-01385 Grill Installation Certain faces allow for installatio
64 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 GS2 Remote Installation Packing List Transmitter B
Optional Equipment (for qualified installers only) 65 Travis Industries 4140611 100-01385 Base Wiring Diagram BlowerHookupPilot SensorApplia
66 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 GS2 Remote Wiring Diagram OrangeYellowSystem JumperP
Optional Equipment (for qualified installers only) 67 Travis Industries 4140611 100-01385 Installation 1. Removetheconcealmentcoverfromth
68 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 3. Removethecontrolpanelandplaceface‐downinfront
Optional Equipment (for qualified installers only) 69 Travis Industries 4140611 100-01385 6. PullthebaseIFCforwardto accessthewiring(
Installation (for qualified installers only) 7 Travis Industries 4140611 100-01385 Packing List Propane Conversion Kit Log Set Firestop (
70 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 8. Disconnectthefollowing: Power (3 wires) Main har
Optional Equipment (for qualified installers only) 71 Travis Industries 4140611 100-01385 12. Thesteppermotor(adjustableregulator)hasanins
72 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 Instructions for Using the Optional Blower with GS2 Remo
Optional Equipment (for qualified installers only) 73 Travis Industries 4140611 100-01385 13. Wiretheaccentlightforremoteoperation.When u
74 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 15. Attach the following: Power (3 wires – make sure ori
Optional Equipment (for qualified installers only) 75 Travis Industries 4140611 100-01385 16. Disconnect the IPI/CP switch from IPI/CP wires.
76 Optional Equipment (for qualified installers only) Travis Industries 4140611 100-01385 20. Route the battery box harness through the control pa
Optional Equipment (for qualified installers only) 77 Travis Industries 4140611 100-01385
78 Index Travis Industries 4140611 100-01385 Index Additional Items Required ... 7 Approved Vent Configurations ...
8 Installation (for qualified installers only) Travis Industries 4140611 100-01385 Massachusetts Requirements NOTE: The following requirements refe
Installation (for qualified installers only) 9 Travis Industries 4140611 100-01385 Top Vent or Rear Vent Configuration This appliance is shipped